Showing results: 1 - 15 of 430 items found.
-
Entes Elektronik
ENTES Reactive Power Factor Controllers try to match the system''s power factor which is defined as the ratio of the active power to the apparent power to the user defined power factor value by controlling the facility''s reactive power using capacitor banks.
-
-
-
Rishabh Instruments Pvt. Ltd.,
Is an intelligent power factor controller for reactive power compensation. It has 4 / 6 / 8 control outputs with LED Display for target PF.
-
R5&R8 -
Ducati energia S. p. A.
DUCATI energia introduces the new and innovative R5 and R8 power factor controllers. The compactness, the latest technology and the complete range of features make the R5 and R8 models extremely adaptable to any application context in the field of power factor correction systems for both single-phase and three-phase networks of low and medium voltage with a lot of connectivity options.
-
HV/MV -
Ducati energia S. p. A.
Power Capacitors for medium voltage network:Ducati Energia proposal includes range of single and three-phase capacitors up to 800 kVAr with max HSV of 36kV.Upon request,we provide them with internal fuses stainless steel cases,inrush reactors,expulsion fuses as well.System is designed according to the specific application and it is composed by current transformers (CT),voltage transformers (VT) and relais.
-
-
*(0.2%ACC.) : TDPF. *(0.5%ACC.) : TSPF -
Kusam Electrical Industries Limited
• Dual Aux. Power 110/220V AC• High Accuracy 0.2% RO at 23 °C± 5 °C• High Dielectric Strength 2.6KV AC / Min, Between Input / Output/ Power Case• ABS Plastic Case, DIN Rail or Wall Mounting
-
Model -KM PFR 9-6 / 9-12 -
Kusam Electrical Industries Limited
The pioneers & leaders in high quality power factor controllers & maximum demand controllers, now introduce 2 new economy models of power factor controllers. These controllers have microprocessors for automatic control of power factor. It has digital indication for power factor.
-
Elmeasure India Pvt. Ltd
Power factor controlling based on the capacitor bank switching historyCapacitor is automatically disabled when it is deteriorated beyond a certain levelAutomatically learns the number of capacitors connected and the value.Capacitance-based power factor correction takes care of variation in voltage and frequency.Controlling based on VAR parameter and availability of built-in alarms Flexibility for site programmability of CT ratio suitable for any load
-
ST-2000 Cos∮ -
Standard Electric Works Co., Ltd
● Principle : Phase angle sensing transducer● Rated Accuracy : ±3% phase angle● Scale : Power Factor:Lead 0 – 0.3 – 1.0 – 0.3 – 0 Lag Power Angle: Lead 90° – 0° – 90° Lag● Effective Power Factor Measuring Range : Lead 0.5 – 1.0 – 0.5 Lag● Scale Length : Approx. 135mm(5-3/8”)● Frequency Influence : Within ±1.5° phase angle at 45 to 65Hz
-
3282(280V,1875W / 3700VA ) -
PRODIGIT Electronics Co, Ltd.
3282 power Factor RLC Load built-in 16-bit A/D and DSP precision measurement circuit, provides accurate measurements, measurement items have Vrms, Arms, Watt, VA, CF, PF, THD, VTHD, ITHD, Ipeak, Amax, Amin, Vmax, and Vmin. In addition to these measurement functions, it also provides time measurement,products such as UPS, fuses and circuit breakers etc. trip or blow time and transfer time for Off-line UPS
-
Nippen Electrical Instruments Co.
NIPPEN Model UNO+ is used for measurement and control of PF using Reactive power compensation. Capacitor banks are suitably switched ON and OFF automatically to provide necessary compensation.An Intelligent switching algorithm (Wear leveling) ensures uniform aging of the capacitors used to achieve the Target PF. An Alarm function ensures protection of capacitor banks against abnormality in voltage, current and sets value of capacitors whenever these are beyond the higher and lower threshold limits.CT polarity is automatically sensed internally in the event of reverse connection.
-
Varcorder -
SensorLink
The Varcorder measures and records Amps and Power Factor. A voltage constant is then applied in software to calculate VARs. The Varcorder uses the same current sensor technology as the original Ampstik. This patented amp sensor does not use magnetic materials and has no moving parts. The opening of the sensor is electronically closed, and external currents are electronically rejected. The accuracy, external current reject, and range of currents measured by the patented amp sensor substantially exceed the performance of the best clamp-on sensors. The true power factor is calculated by measuring the electric field in comparison with the current reported from the amp sensor. The key feature of the unit is the ability to leave it deployed on the line to record readings every 15 minutes for 90+ days. It easily attaches to the line with a standard shotgun style hotstick. Once on the line, it immediately begins to collect and record the current and power factor on the line.
-
Supreme Instrument Laboratories
The Principle of working is Electo-dynamometer type for Wattmeters. Portable dynamometer type single phase Single element Wattmeter housed in laminated wooden cabinet size 235 mm length x 200 mm width x 180 mm height, with detachable lid, black bakelite panel fitted with anti-parallax mirror scale, knife edge pointer, rubber footings, carrying handles, locking arrangements.